← Back to tools

Gas Pipe Sizer

Fuel gas piping by the longest length method per the 2025 California Plumbing Code (NFPA 54)

Pressure drop 0.5 in. w.c, supply under 2 psi.

ft

Meter or regulator to the most remote outlet.

Btu/cf

From the gas supplier (1214.3).

Connected load Natural gas · Schedule 40 steel
250MBH250cfh

Read at the 60 ft row for 60 ft, 0.5 in. w.c. drop, 1,000 Btu/cf.

SectionSizeCapacity
Main from the meter
250 MBH · 250 cfh
1″
257 cfh
To warm air furnace, single family
100 MBH · 100 cfh
¾″
137 cfh
To water heater, storage, 50 gallon
50 MBH · 50 cfh
½″
65 cfh
To range, freestanding, domestic
65 MBH · 65 cfh
½″
65 cfh
To clothes dryer, Type 1 (domestic)
35 MBH · 35 cfh
½″
65 cfh

Enter the load each section carries, the sum of the outlets past it. Every section is read at the same longest length (1215.1.1).

Longest length method (1215.1.1): every section is sized for the load it carries, read at the length from the point of delivery to the most remote outlet, rounded up to the next table row. Capacities are the 2025 California Plumbing Code Section 1215.3 sizing equations with Table 1215.3’s Cr and Y at the inside diameters of Tables 1215.2, rounded to three figures as the tables print them; they agree with the tables. Natural gas loads are converted to cfh at the heating value entered (1214.3). The specific gravity is the tables’ (0.60 natural, 1.50 propane); for other gases use the supplier’s factors (1214.1). Appliance inputs default to Table 1208.3.1 typical values; use the nameplate input (1214.2). CSST is sized from the manufacturer’s tables.

Appliances
FixtureEach
MBH
QtyTotal
MBH
Warm air furnace, single family100
Warm air furnace, multifamily, per unit
Hydronic boiler, single family
Hydronic boiler, multifamily, per unit
Space and water heating boiler, single family
Space and water heating boiler, multifamily, per unit
Water heater, storage, 30 to 40 gallon
Water heater, storage, 50 gallon50
Water heater, instantaneous, 2 gpm
Water heater, instantaneous, 4 gpm
Water heater, instantaneous, 6 gpm
Water heater, circulating or side-arm
Range, freestanding, domestic65
Built-in oven or broiler, domestic
Built-in top unit, domestic
Clothes dryer, Type 1 (domestic)35
Gas fireplace, direct vent
Gas log
Barbecue
Refrigerator
Gaslight
Not listed

Commercial and other appliances: enter the nameplate input in thousands of Btu/h.

Total4 fixture types4250MBH

Enter or ↓ moves down · + and − step the count · paste a column from a spreadsheet to fill down

Inputs default to the approximate values of 2025 California Plumbing Code Table 1208.3.1 (NFPA 54 Table A.5.3.2.1); type the nameplate input in the Each column to replace one.